Rotronics Training Facility is a world-class facility for Fire Fighting, Rescue, Safety and Emergency Services. Trainers are Foreign & local Industry Experts, BFP Special Rescue Unit, Red Cross and other government institutions. This one of a kind Training Facility in the Philippines includes a wide lecture room for 50 persons, accommodation for 30 persons for stay-in, canteen, 10 toilets and a wide parking area. It also includes complete equipment needed for the Fire Fighting, Rescue, and Safety Training.

Let us lessen your workload and let the expertise of our company handle the task of preparing and training your personnel in an emergency situation.  Your personnel will experience the actual scenarios and learn the latest techniques for Fire Fighting, Rescue, Safety, and Emergency Operations that will prepare them well in times of emergencies. Nothing beats good training or boosting self-confidence in handling emergency situations that result in saving lives and property assets. 

awd

Services
 
 

CALIBRATION / FLOW TEST GUIDELINES

The following table summarizes MSA’s required frequency for overhaul and flow testing:

AVERAGE SCBA USAGEREGULATORS AUDI LARM OVERHAUL FREQUENCYFLOW TEST FREQUENCY
1 cylinder per day or greaterEvery 3 yearEvery year
1 cylinder every other dayEvery 8 yearEvery year
1 cylinder per week or lessEvery 15 yearEvery year

A decision to retire apparatus should be based on a SCBA’s performance data and whether that data meets the specified level of performance as defined in the maintenance requirements from MSA.

*The unit of SCBA use is defined as the consumption of one 30-minute cylinder of air. If three cylinders of air are used, the SCBA would be considered to have been used three times.

 

 

HYDROSTATIC TESTING

Hydrostatic testing is required under 49 CFR 180.205 to ensure the integrity of pressurized cylinders. These include cylinders of Self Contained Breathing Apparatus (SCBA) and Emergency Life Support Apparatus (ELSA).

 

 

HOW TO KNOW IF YOUR SCBA IS IN NEED OF HYDROSTATIC TESTING?

Table below is the information guide needed on when to have your SCBA be hydrotested starting from the Date of Manufacture, which indicated on the body of the cylinder. If it undergone a hydrotest before, see the date on the round metal disk wrapped around the neck of the cylinder. Contact us if you have inquiry.

CYLINDER TYPEHYDROSTATIC TEST REQUIRED EVERY ( ) YEARSSERVICE LIFE IN YEARS
Fully-wrapped Carbon515
Fully-wrapped Fiberglass315
Hoop-wound Fiberglass315
Aluminum315
Steel3>15 / until it fails HydroStatic Test

 

 

REFILL

SCBA Tanks should be refilled every after use to ensure full length of service when needed. We conduct refilling of grade D breathing air to all types of SCBA cylinders.

 

 

 

GAS DETECTOR SERVICES

CALIBRATION

MSA XCell Sensors have an expected life of more than four (4) years which translates to fewer sensor replacements during the instrument’s life and lower costs. MSA’s gas detection instruments are designed to notify users as sensors reach end-of-life which ensures reliability of the instruments. It is vital that portable gas detectors are maintained and calibrated properly. All sensors can eventually expire due to loss of sensitivity, slowed response time or both, with exposure to work conditions. MSA recommends full calibration of gas detectors every 6 months or at least once a year to ensure maximum accuracy of the instrument.

REPLACEMENT OF SENSORS

We keep an inventory of MSA sensors, allowing us to provide quick replacements and get your gas detector back in service as soon as possible. As we are a distributor of MSA, we are limited to their sensors only.